Monitoring a compressed air refrigeration dryer is critical to increase energy efficiency, ensure product quality, prevent damage to machinery, identify maintenance needs, and achieve cost savings. This contributes to the smooth operation of compressed air systems in various industrial applications.
Our sensor technology and evaluation electronics have undergone continuous advancements, leading to enhanced precision under varying ambient conditions and a higher signal resolution. Like their predecessors, the new dew point sensors offer long-lasting, stable, and reliable measurement results. Insensitive to condensation, our sensor element is safeguarded from direct contact with contaminated particles by a robust stainless-steel sintered cap.
Recommendation:
Mounting with a standard measuring chamber for compressed air up to 16 bar.
Advantage:
Effortless installation with quick coupling.
Special features:
• Exceptionally stable over the long term.
• Analog output 4...20 mA for dew point.
• Condensation-resistant.
• Rapid response time.
• Pressure-resistant up to 350 bar (special version).
• NEW: Modbus-RTU interface.
• NEW: Enhanced sensor signal resolution due to improved evaluation electronics.
• NEW: On-site sensor diagnostics with a portable device or CS Service Software.
Readable via Modbus:
TECHNICAL DATA FA 510/515
Measuring range | -80…20 °Ctd, -20…50 °Ctd |
Accuracy | ± 1 °C at 50…-20 °Ctd ± 2 °C at -20…-50 °Ctd ± 3 °C at -50…-80 °Ctd |
Pressure range | -1…50 bar Special version up to 500 bar |
Power supply | 24 VDC (10…36 VDC) |
Protection class | IP 66 |
EMC | In acc. with DIN EN 61326-1 |
Operating temperature | -20…70 °C |
Connection | M12, 5-pin |
PC connection | 4…20 mA = -80…20 °Ctd 4…20 mA = -20…50 °Ctd FA 510: 4…20 mA (3-wire) FA 515: 4…20 mA (2-wire) |
Burden for analogue output | < 500 Ω |
Screw-in thread | G 1/2″ Stainless steel Optional: UNF 5/8", NPT 1/2" |
Dimensions | Ø 30 mm, length approx. 130 mm |
Choose units | % RH, °Ctd, g/m³, mg/m³, ppm V/V |
Scaling | 4…20 mA change |