Customization: | Available |
---|---|
Brand: | CS |
Customized: | Non-Customized |
Still deciding? Get samples of US$ 1200/Piece
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Ensuring the optimal performance of a compressed air refrigeration dryer is vital for maximizing energy efficiency, maintaining superior product quality, preventing machinery damage, identifying maintenance needs, and achieving significant cost savings. This, in turn, ensures the smooth operation of compressed air systems across diverse industrial applications.
Our sensor technology and evaluation electronics have been meticulously refined, resulting in enhanced precision at various ambient temperatures and improved sensor signal resolution. As with previous models, the new dew point sensors boast long-lasting stability and reliable measurement results. The sensor element resists condensation and is safeguarded from direct contact with contaminants by a robust stainless-steel sintered cap.
Recommendation:
Mounting with standard measuring chamber for compressed air up to 16 bar
Advantage:
Effortless installation with quick coupling
Special Features:
• Exceptionally stable over long periods
• Analog output 4...20 mA for dew point
• Resistant to condensation
• Rapid response time
• Pressure-resistant up to 350 bar (special version)
• NEW: Modbus-RTU interface
• NEW: Enhanced sensor signal resolution thanks to improved evaluation electronics
• NEW: On-site sensor diagnostics with a portable device or CS Service Software
Readable via Modbus:
TECHNICAL DATA FA 510/515
Measuring range | -80…20 °Ctd, -20…50 °Ctd |
Accuracy | ± 1 °C at 50…-20 °Ctd ± 2 °C at -20…-50 °Ctd ± 3 °C at -50…-80 °Ctd |
Pressure range | -1…50 bar Special version up to 500 bar |
Power supply | 24 VDC (10…36 VDC) |
Protection class | IP 66 |
EMC | In acc. with DIN EN 61326-1 |
Operating temperature | -20…70 °C |
Connection | M12, 5-pin |
PC connection | 4…20 mA = -80…20 °Ctd 4…20 mA = -20…50 °Ctd FA 510: 4…20 mA (3-wire) FA 515: 4…20 mA (2-wire) |
Burden for analogue output | < 500 Ω |
Screw-in thread | G 1/2″ Stainless steel Optional: UNF 5/8", NPT 1/2" |
Dimensions | Ø 30 mm, length approx. 130 mm |
Choose units | % RH, °Ctd, g/m³, mg/m³, ppm V/V |
Scaling | 4…20 mA change |