Michell Easidew -100 to 20 Deg C 4-20 mA Output RS485 Communication Dew Point Sensor
The Easidew Transmitter is meticulously engineered for straightforward operation, boasting all essential features to ensure seamless installation and hassle-free use. For the first time, dew point measurement is as easily accessible as temperature and pressure, thanks to this fully configured and calibrated transmitter. It is ready for instant integration into your air or gas management and control systems, making your operations more efficient than ever.
Highlights:
• 2-wire loop powered connection for simplicity
• Measures dew point or ppm moisture content
• IP66 (NEMA 4) rating for superior durability
• Provides excellent sensor protection
• Measurement range: -100 to +20°C (-148 to +68°F)
• Operating temperature range: -40 to +60°C (-40 to +140°F)
• Delivers fast and reliable response
Performance:
Measurement range (dp): -100 to +20°C (-148 to +68°F) dew point
Accuracy (dp): ±2°C (±3.6°F) dew point
Response time: 5 mins to T95 (dry to wet)
Repeatability: 0.5°C (0.9°F) dew point
Electrical output/input:
Output signal: 4-20 mA (2-wire connection, current source)
User configurable over range
Output: Dew point, moisture content for ppmV
Output range: Dew point: -100 to +20°C (-148 to +68°F)
Moisture content in gas: 0-3000 ppmV
Supply voltage: 12-28 VDC
Load resistance: Max 250 Ω @ 12 V (500 Ω @ 24 V)
Current consumption: 20 mA max
Operating conditions:
Operating humidity: 0-100% RH
Operating temperature: -40 to +60°C (-40 to +140°F)
Operating pressure: 45 MPa (450 barg / 6500 psig) max
Flow rate: 1 to 5 Nl/min (2.1 to 10.6 scfh) in standard sampling block; 0 to 10 m/sec
standard sampling block; 0 to 10 m/sec mounted in
(0 to 32.8 fps) direct insertion
Temperature coefficient: Temp compensated across the operating temp range